PRODUCT DETAILS
120W Programmable Battery Charger for Electric Vehicle Universal AC Input

The EVC-AA-120-XXYYYY is a 120 Watt, constant power, factory programmable charger for use in charging Lithium Ion and other chemistry battery systems used in Electric Vehicles. The charger can be programmed to the customer's current/voltage requirements up to 120 Watts of power. See table below for available ranges.


Features
Universal AC Input / Full Range
90 - 305 VAC Input
High Reliability
Efficiency up to 89%
Power Factor up to 0.98 min @ 110 VAC Full Load
Over Voltage Protection
Short Circuit Protection
Over Temperature Protection
Open Circuit Protection
Waterproof IP67 Enclosure
RoHS Compliant
5 Year Warranty


Model Selection

Model Number

Programmable Output Charging Current Range

Voltage Range

EVC-24-120-XXYYYY*

EVC-36-120-XXYYYY*

EVC-48-120-XXYYYY*

3800 mA to 4200 mA

2527 mA to 2793 mA

1938 mA to 2142 mA

15 V - 30 V

22.5 V - 45 V

29 V - 58.8 V

*XXYYYY specifies nominal programmable Voltage (XX) based on the nominal output charging current (YYYY).


Specifications
Input Parameters
Input Voltage Range*
*Designed to optimum performance at 110 and 230 nominal lines
MIN TYP MAX 90
110
305
 
VAC
Input Frequency TYP 47 - 63 Hz
Power Factor
110 VAC Input, Full Load 230 VAC Input, Full Load
 
MIN
 
0.98
0.95
 
Input Current
110 VAC, Continuous
230 VAC, Continuous
 
MAX
 
1.5
0.75
 
A rms
Efficiency 115VAC Full Load 230VAC Full Load  
TYP TYP
 
86
89
 
%

 

24V Output Parameters

24V Charging Current Setting Range

MIN TYP MAX

3800

4000

4200

 

mA

24V Charging Voltage Range

MIN MAX

15

30

V

The output charging current can be programmed between 3800mA and 4200mA, while the maximum output voltage increases up to 30V accordingly based on the principle of 120W maximum output power.

Output Overshoot/Undershoot (Power On/OFF) Overshoot (output peak current) 5.6A maximum @ nominal AC input, full load, 25 ºC. Measured with 20MHz bandwidth.

 

36V Output Parameters

36V Charging Current Setting Range

MIN TYP MAX

2527

2660

2793

 

mA

36V Charging Voltage Range

MIN MAX

22.5

45

V

The output charging current can be programmed between 2527mA and 2793mA, while the maximum output voltage increases up to 30V accordingly based on the principle of 120W maximum output power.

Output Overshoot/Undershoot (Power On/OFF) Overshoot (output peak current) 5.6A maximum @ nominal AC input, full load, 25 ºC. Measured with 20MHz bandwidth.

 

48V Output Parameters

48V Charging Current Setting

Range

MIN TYP MAX

1938

2040

2142

 

mA

48V Charging Voltage Range

MIN MAX

29

58.8

V

The output charging current can be programmed between 1938mA and 2142mA, while the maximum output voltage increases up to 58.8V accordingly based on the principle of 120W maximum output power.

Output Overshoot/Undershoot (Power On/OFF) Overshoot (output peak current) 5.6A maximum @ nominal AC input, full load, 25 ºC. Measured with 20MHz bandwidth.

 

All Models      
Current Accuracy MAX ±5 %
Voltage Accuracy MAX ±2 %
Output Power MAX 120 W
Ripple and Noise - Iout
with typical CV load at 25ºC 100- 240VAC input measured at
20 MHz bandwidth
 
MAX
 
20
 
% Iout
Turn-on Delay Time Full Load @ 110 VAC Full Load @ 230 VAC  
MAX
 
2
 
s
Rise Time
@ 25ºC, Full Load
MAX 150 mS
Current Temperature Coefficient
0 ºC < Tcase <tcmax
MAX 0.05 % / ºC
Voltage Temperature Coefficient
0 ºC < Tcase <tcmax
MAX 0.05 % / ºC

Isolation Test: Primary to Secondary

3750 VAC

10 mA Max/60 seconds

(3 seconds for production)

Isolation Test: Primary to Ground

1875VAC

10 mA Max/60 seconds

(3 seconds for production)

Isolation Test: Secondary to Ground

500VAC

10 mA Max/60 seconds

(3 seconds for production)

Leakage Current: @240VAC/50Hz

0.50mA Max

Ground Resistance:

@ 25A, 1 minute

MAX

0.1

Ω

Isolation Resistance: Primary to Secondary with 500 VDC test voltage

 

MIN

 

100

 

MTBF: (MIL-HDBK-217F 25ºC,

230VAC input and full load output)

≥ 200,000

Hours

Life Time: @ 50ºC, 230 VAC input

and full load output

≥ 50,000

Hours

Temperature - Operating

MIN MAX

-20

+60

ºC

Temperature - Storage

MIN MAX

-40

+85

ºC

Relative Humidity

10% - 100%

Weatherproof

IP64 for Enclosure

Case Size

10.75" x 1.93" x 1.59"

273mm x 49mm x 40.5mm

Unit Weight

0.8 kg

Agency Approval

Designed to meet CE and UL1012

Protection

Short Circuit Protection

Auto-Recovery - return to normal when fault condition is removed

 

Over Voltage Protection

Can be programmed at 3-5V over maximum voltage output. Auto-recovery during over voltage protection and will return to normal operation when fault condition is removed.

 

Over Temperature Protection

The unit will go into thermal protection when it is overheating. The unit will enter auto- recovery mode and will self-recover when the temperature becomes normal.

Open Circuit Protection

When output is open, power supply will enter auto-recovery and return to normal operation after fault condition is removed.

*Notes:

  1. When the output voltage is less than set maximum voltage, charger will be in CC mode. When the output voltage reaches and is above ±2% of the set maximum voltage, the charger will be in CV mode.
  2. Vibration - 10 to 300 Hz sweep at a constant acceleration of 1.0G (Breadth: 3.5mm) for 1 hour for each of the perpendicular axes X, Y, Z.
  3. Specifications are subject to change without notice.


Charging Curve
Charging curves are defined at maximum voltage and current.